Anti-explosion LED high bay light

【1】Product Appearance

 

Specialty:

【1】Using high powerCOB LEDS, the lamp’s luminous efficiency can reach 80-100LM/W, and CRI>80Ra;

Fins heatingdissipation design enables the LED Tj within 85℃, and power up to 200W, lifespan more than 35,000hours; with protecting rate:IP65.

 

【2】The UFO high baylight is verified and certified according to standards for safety asbelow:GB3836.1-2010 Explosive atmospheres Part 1:Equipment General RequirementsGB3836.8-2003 Explosive atmospheres Part8:Electrical apparatusfor explosive gasatmos-pheres-Part8:Encapsulation “n” with Ex-marking ExnRⅡT4Gc.

 

【3】The light can beused in :Normally,a place in which an explosive atmosphere in the form ofexplosive dust or combustible fibre in mixture with air is likely to occurcontinuously or frequently in short time, or for long periods in normaloperation. According to the classification of explosion proof grade andapplication, the light can be use in Zone2.Surface temperature of item forsafety:≤135℃,such an arealighting site like factory,warehouse,except mine.

 

【2】Shape Structure

Shell Material:AluminumAlloy      Shell Color:silver white

Net Weight:8.3 Kg     Unit:mm  ±2mm

 

【3】Explosion-proof Parameters

1)Explosion-proof(Grade)

ExnRⅡT4Gc

 (1)Ex—Explosion-proof

 

(2)nR-Explosion proofform code of explosion proof electric equipment, nR for restrict breathing type,the others: D for explosion suppression type; IA for flameproof intrinsicallysafe type; MB for pouring type ... .;

 

(3)II-Explosion proofelectrical equipment is divided into type Ⅰ,Ⅱ,Ⅲclass; class I used for coalmine gas environment; class II, III used for other explosive gases electricequipments except coal mines which can easily generate gas.

 

(4)T4-equipmentexternal surface temperature range ( T4 means the temperature of any point onthe external surface of UFO explosion-proof mining lamp ≤ 135 ℃);

 

(5)Gc-Electricequipment protection level, and has a corresponding relationship to its usedplace, Gc level of protection for the general, and it can be used in explosivegas environment --Zone 2;

2)Hazardous area classification

 

                                     
 

Explosive  substance

 
 

Area  definition

 
 

 

 

Chinese  standard

 
 

 

 

Foreign  standards

 
 

Gas(ClassⅠ)

 
 

Under normal  circumstances, the explosive gas mixture continuously or long time existence.

 
 

 

 

Zone 0

 
 

Div.1

 
 

Under normal  circumstances, the explosive gas mixture is likely to existent site

 
 

 

 

Zone 1

 
 

Under normal  circumstances, the explosive gas mixture is not possible appear, Only in  abnormal circumstances, occasionally or short time existed site ;

 
 

 

 

Zone 2

 
 

Div.2

 
 

Dust or fiber(ClassⅡ/ClassⅢ)

 
 

Under normal  circumstances, explosive dust or combustible fibre and air mixture may be  continuous, a short time frequent appear or long time existence.

 
 

 

 

Zone 10

 
 

Div.1

 
 

Under normal  circumstances, explosive dust or combustible fibre and air mixture can not  appear, just in case of abnormal condition, occasionally or short time  appears.

 
 

Zone 11

 
 

Div.2

 

 

3)Gas temperature group

 

                                       
 

Temperature  category

 
 

Explosion  proof electrical equipment surface temperature

 
 

Common  explosive gas

 
 

T1

 
 

≤450℃

 
 

Methane、Toluene、Methyl ester、Ethane、Propane、Acetone、Acrylic acid、Benzene、Styrene、Carbon  monoxide、Ethyl acetate、Acetic acid、Chlorobenzene、Methyl acetate、Ammonia、Acrylic ester、Two ether、City gas、Hydrogen、Water gas

 
 

T2

 
 

≤300℃

 
 

Methanol、Ethanol、Ethyl benzene、Propyl alcohol、Propylene、Butyl alcohol、Butane、Butyl acetate 、Amyl acetate、Cyclopentane、Butadiene、Epoxy propane、Ethylene、Acetylene

 
 

T3

 
 

≤200℃

 
 

Pentane、Amyl alcohol、Hexane、Hexyl alcohol、Heptane、Octane、Ring of  ethanol、Turpentine oil、石Naphtha、 Petroleum  (gasoline )、Fuel oil、Amyl  alcohol four、Two ether、Acrolein、Hydrocarbon

 
 

T4

 
 

≤135℃

 
 

Acetaldehyde、Tetrafluoroethylene、Trimethylamine、Ethyl ether、Two ether

 
 

T5

 
 

≤100℃

 
 

Carbon  disulfide

 
 

T6

 
 

≤85℃

 
 

Acid ethyl  ester、Nitrous acid  ethyl ester

 

 

This seriesexplosion-proof lamp temperature group is T4, according to the above standarddata, this series lamp can be used in the warehouse, workshop in the scope ofT1, T2, T3, T4, and related places that require explosion-proof lamp lighting canbe applied.

 

【4】Parameters

 

 Input VoltageAC100~240V Color Rendering IndexRa>80
 Frequency Range50~60HzBeam Angle100°
Power Factor>0.97LED Reduction Rate1~3% / 1,000Hrs
Power Efficiency>90%Color Temperature2700~7000K
LED Working VoltageDC30~36VWorking Temperature-20℃~+45℃
LED Power80WIP GradeIP65
Total Power88WWorking Life-span>35000H
Luminous Efficiency80-100lm / WPower lineVDE  3×1.5mm2
Connect wiresBrown→L   /Blue→N  Yellow or Green→G  

 

【5】Luminous flux reduction diagram

1,The data abovewas testing at environment temperature of 25 celsius degree after 1000 hours constantlighting.

2, Theenvironment condition will affects luminous flux reduction. Luminous flux willdrops faster at a higher temprature or a longer lighting time.

 

【6】Photomatric Data

【7】IlluminationDistance/illuminance/Irradiated Area

【8】Packing specification

Body(L)412×(W)312×(H)428mm   1PC/CTN    10Kg

Reflector(L)432×(W)432×(H)534mm   10PCS/CTN   4.5Kg

 

【9】Using and installation instructions

 

(1)Pleasefirstly install the reflector properly on the heat sink, and screw down.

(2)Then screwdown the hoop into the top cap.

(3)Hang the bodylamp on the installation site.

(4)Please hang thechaining steel wire on another installation device.

(5)Connect LiveWire/Null Wire/Ground Wire to electric cable properly and switch on.

 

Attentions:

1.A licensedelectrician must undertake this installation. Please check the lamp carefully  before installation,Forbidden toopen the lid when charged;

2.Please followup the installation procedures, make sure the screws been wrested very tightly,the wires been connected properly, as attached installation instruction.

 